Imitation Modeling of the Daily Pulse Signal for Long-Term Monitoring Systems
DOI:
https://doi.org/10.20535/RADAP.2019.77.66-73Keywords:
system for long-term monitoring, verification, simulation, daily pulse signal, softwareAbstract
The imitation model of the daily (24 hours) pulse signal is developed on the basis of its mathematical model in the form of the periodically elongated sums of two functions with normal distribution and exponential attenuation. Unlike existing models this one takes into account the randomness arising as a result of the internal and external noises influence, periodicity related to the nature of the pulse signal generation, changing of the oscillation phase as a result of the vessels stiffness changing, the amplitude of the direct and reflected waves of the human vessels blood flow and the day and night structure (i.e. changes in the human cardiovascular system and brain functioning during the day and night). The imitation model makes it possible, based on known medical parameters, to simulate the daily pulse signals of pathologies and norms for the task of the methods for such signals processing in the long-term monitoring systems verification. This is important in the timely diagnosis of the human vessels state for the correct diseases treatment and prevention. Based on the imitation model and the Matlab environment software the algorithms of the daily pulse signal processing and the corresponding graphical user interface are developed. The magnitudes of the pulse signals amplitude, durations, moments of the blood filling maximum time and a number of the other parameters which are characteristic of the pulse signal direct and reflected waves, as well as the number of the day and night stages and their time duration are the input data for such signals simulation. The testing procedure of the developed software for the daily pulse signals modeling is carried out. It is established that obtained simulated implementation of daily pulse signals provide a complete reproduction of the experimental signals form in time and amplitude parameters of the direct and reflected waves. This gives grounds to assert that the developed imitation model is suitable for using in the long-term monitoring systems.Downloads
Published
2019-06-30
Issue
Section
Radioelectronics Medical Technologies
License
Copyright (c) 2019 L. V. Hvostivska, H. M. Oksukhivska, M. O. Hvostivskyy, H. M. Shadrina
This work is licensed under a Creative Commons Attribution 4.0 International License.
Authors who publish with this journal agree to the following terms:- Authors retain copyright and grant the journal right of first publication with the work simultaneously licensed under a Creative Commons Attribution License that allows others to share the work with an acknowledgement of the work's authorship and initial publication in this journal.
- Authors are able to enter into separate, additional contractual arrangements for the non-exclusive distribution of the journal's published version of the work (e.g., post it to an institutional repository or publish it in a book), with an acknowledgement of its initial publication in this journal.
- Authors are permitted and encouraged to post their work online (e.g., in institutional repositories or on their website) prior to and during the submission process, as it can lead to productive exchanges, as well as earlier and greater citation of published work (See The Effect of Open Access).